search »
» About us
» Integrated Solutions
» Sensor
» Switches
» Process Products
» VIP Access
» Document Download

Get Adobe Acrobat Reader

In order to view PDF documents, you need Adobe Acrobat Reader version 4.0 or later, available for free download from Adobe Systems (click icon to access the web site).
Compact Die-cast Safety
Limit Switches
Features

UL/CSA markings provided
(") contact forced open mechanism provided. (N.C. contact only)
High sealing ability (IP67)
Safety interlock switch made of die-cast.
 

Performance

Standards Conformed standards Product related: IEC 60947-5-1, EN 60947-5-1
(->)
Machine related: IEC 60204-1, EN 60204-1
Approved standards UL
Structure Protective structure IP67 (IEC 60529)
Electrical shock protection Class I (IEC 60536)
Contamination degree of
operating environment
Contamination degree 3
Internal switch Slow action
Electrical
performance
Electrical rating See separate Table 1.
Dielectric strength Between non-continuous terminals: 2,500Vac, 50/60Hz for 1min.
Between esch terminal and non-conducting metal part: 2,500Vac, 50/60Hz for 1min.
Between each terminal and ground: 2,500Vac, 50/60Hz for 1min.
Insulation resistance 100M or more (by 500Vdc Megger)
Rated energizing current (Ith) 6A
Short-circuit protective device Breaking fuse 6A type gG (gl)
Rated insulation voltage (Ui) 400V IEC 60947-5-1, 300V UL508
Conditional rated
short-circuit current
1,000A
Rated impulse withstanding
voltage (Uimp)
4,000V
Mechanical
performance
Impact resistance 250m/s2 (18ms) IEC 60068-2-27
Vibration resistance 250m/s2 (10 to 500Hz) IEC 60068-2-6
Allowable operating speed Minimum operating speed: 0.001m/s
Maximum operating speed: (30° dog is used.)
LJM-B502 : 0.1m/s, LJM-B515 : 1.5m/s
Life Mechanical life 10million operations or more
Electrical life 4million operations (3,600 operations/hr. or less)
Environmental
conditions
Operating temperature range -25 to +70°C (non-freezing)
Operating humidity range 85%RH or less
Recommended
tightening torque
Body 1.2 to 1.5Nm (M4 hexagon socket head cap bolt)
Note 1 The values stated in the above Table are common to all LJA10 series models.
Note 2 The values for the roller lever type are those obtained when the lever length is 30mm.
Table 1. Electrical rating
AC-15: B300
(Ue=240V, Ie=1.5A)
DC-13: R300
(Ue=250V, Ie=0.1A)
Category used AC-15:
DC-13:
Solenoid load
Solenoid load
Ue: Rated operating voltage
Ie: Rated operating current
 
Top
 
 

Address: 3323 Kifer Rd.; Santa Clara, CA; 95051 Phone: 1-866-SENSOR1 Fax: 1-602-216-8211
---------------------------------------------------------------------------------------------------------------------------------------------------------
Yamatake Sensing Control, Limited. © Copyright 2007 Terms and Conditions | Privacy Policy