search »
» About us
» Integrated Solutions
» Sensor
» Switches
» Process Products
» VIP Access
» Document Download

Get Adobe Acrobat Reader

In order to view PDF documents, you need Adobe Acrobat Reader version 4.0 or later, available for free download from Adobe Systems (click icon to access the web site).

Safety Limit Switches

Features:
(") mark (symbol mark for control switch with positive open circuit operation) is provided to ensure acquisition of the EN standard approval.
Safety limit switch conforming to the EN 50041 standard
UL/CSA/CE markings are provided, suitable for machines to be exported to North America and Europe.
N.C./N.O. electrically independent contact (Zb) is achieved with snap action mechanism.
Use of twin-contact structure improves the contact reliability.
Mounting pitch compatible with that of LS general-purpose limit switch having abundant excellent operation results.
A wide variety of actuators provided.
High sealing ability applicable to immersion proof type (JIS) and IP67 (IEC 60529).

Performance

Standards Conformed standards JIS C 4508/JIS C 8201-5-1, IEC 60947-5-1, EN 50041 (mounting hole dimension only)
Approved standards EN 60947-5-1(TÜUV)/UL(E 96090)/CSA
Structure Contact type Zb(EN 60947-5-1)(->)
Contact shape Rivet
Terminal shape Screw (M3 round head screw with square washer)
Protective structure Immersion proof type (JIS), IP67 (IEC 529)
Contamination degree of
operating environment
Contamination degree 3 (EN 60947-5-1)
Electrical
performance
(1) General
characteristics
Electrical rating See separate Table 1.
Dielectric strength Between non-continuous terminals: 2,100Vac, 50/60Hz for 1min.
Between each terminal and non-conducting metal part: 5,300Vac, 50/60Hz for 1min.
Between each terminal and ground: 5,300Vac, 50/60Hz for 1min.
Between different terminals: 5,300Vac, 50/60Hz for 1min.
Insulation resistance 100M or more (by 500Vdc Megger)
Initial contact resistance 25m or less (6 to 8Vdc, energizing current 1A, measured by voltage drop method)
Recommended min.
operating voltage/current
24V-10mA, 12V-20mA
Electrical
performance
(2) General
related
characteristics
Rated operating voltage 400Vac, 250Vdc
Rated energizing current (Ith) 10A
Rated frequency AC voltage, 45 to 65Hz, and DC voltage
Short-circuit protective device BUSSMAN fast acting fuse KTK-10 (10A) or equivalent
Rated insulation voltage (Ui) 500Vac or 275Vdc
Conditional rated
short-circuit current
1,000A (with coil load)
Switching over-voltage Category 3 (IEC 204-1)
Rated impulse withstanding
voltage (Uimp)
6,000V
Electrical protection Class I and Class II (without use of grounding terminal) (IEC 536)
Mechanical
performance
Actuator strength Roller lever type: 49N in operating direction for 1min. or more
Plunger type: 93N in operating direction for 1min. or more
Rod lever type: 12N in operating direction for 1min. or more
Terminal strength Withstand tightening torque strength of 1.0 Nm for 1min.
Impact resistance 300m/s2, contact open is 1ms. or less at free position and operation limit position.
Vibration resistance Frequency: 10 to 55Hz, Peak-to-peak amplitude: 1.5mm, Continuous 2hrs.
Contact open is 1ms. or less at free position and operation limit position.
Allowable operating speed 1mm/s to 0.5mm/s, Min. speed: 0.1s or less in the unstable contact status.
Max. speed: Actuator should not be broken.
Mechanical operating frequency 120 operations/min. or less
Life Mechanical life Lever type: 15million operations or more, Plunger type: 5million operations or more
Electrical life 100,000 operations or more (rated load, open/close frequency: 20operations/min. or less)
Environmental
conditions
Operating temperature range -25 to +70°C (non-freezing)
Operating humidity range 98%RH or less
Recommended
tightening torque
Body 5 to 6Nm (M5 screw)
Terminal 0.6 to 1.0Nm (M3 round head screw with square washer)
Cover 1.3 to 1.7Nm (M4 screw)
Head 0.8 to 1.2Nm (M3.5 screw)
Roller lever 4 to 5.2Nm (M5 screw)
Note 1 The values stated in the above Table are common to all LJA10 series models.
Note 2 The values for the roller lever type are those obtained when the lever length is 30mm.
Table 1. Electrical rating
EN 60947-5-1 UL508
AC-15: Ue=AC 400V, Ie=2A
Ue=AC 240V, Ie=3A
DC-15: Ue=DC 240V, Ie=0.27A
2A/400Vac General Use Load
3A/400Vac General Use Load
0.27A/240Vdc
0.55A/120Vdc
   
Category used AC-15:
DC-13:
Solenoid load
Solenoid load
   
Ue: Rated operating voltage
Ie: Rated operating current
 

Address: 3323 Kifer Rd.; Santa Clara, CA; 95051 Phone: 1-866-SENSOR1 Fax: 1-602-216-8211
---------------------------------------------------------------------------------------------------------------------------------------------------------
Yamatake Sensing Control, Limited. © Copyright 2007 Terms and Conditions | Privacy Policy
Powered by: Lan Services