| Detection
method |
Thru
scan |
Retroreflective |
Diffuse
scan |
| Catalog
listing |
FE8B-TC6(G)
FE8B-TC6V(G)
FE8B-TA6P
FE8B-TA6VP |
FE8B-TMC6
FE8B-TMC6V |
FE8B-RC6
FE8B-RC6V |
FE8B-DC6
FE8B-DC6V |
FE8B-DLC6
FE8B-DLC6V |
| Supply
voltage |
10
to 28Vdc |
| Current
consumption |
Max
30mA (35mA for products with the self-diagnostic
function) |
| Scanning
distance |
5m |
7m |
0.1
to 2m
(reflector: FE-RR8) |
0.3m |
0.5m |
| Target
object |
9
dia. min. (opaque materials) |
50
x 50mm min.
(opaque materials) |
Transparent
and opaque materials |
| Standard
target object |
- |
White
paper 20 x 20cm |
| Operation
angle |
Both
emitter and receiver: 3 to 20° |
Body:
2 to 10° |
- |
| Differential |
- |
20%
max. of scanning distance |
| Output
mode |
NPN
transistor (open collector) |
| Control
output |
Output
switching current: Max. 100mA (resistive
load), output dielectric strength: Max.
30V, residual voltage: Max. 1V (at 100mA
switching current) |
| Self-diagnostic
output |
Operation
mode: Output transistor ON at: incoming
of unstable light.
Output mode: NPN transistor/open collector.
Output switching current: Max. 50mA
(resistive load), residual voltage:
Max. 1V (at 50mA switching current) |
| External
diagnostic function |
When
an input control terminal is connected
to the plus terminal of power supply,
the light emitter stops the light emitting. |
| Response
time |
ON/OFF
time 5ms max. |
ON/OFF
time 30ms max. |
ON/OFF
time 5ms max. |
| Light
emitter |
Infrared
LED |
| Output
indicator (self-diagnostic indication) |
Light
operated (stable light input: green,
unstable light input: red), OFF when
light is blocked., Power indicator of
thru scan emitter: red |
| Ambient
light resistance |
Incandescent
lamp: 3,000lux max., Sun light: 10,000lx
max. |
| Temperature
range |
-20
to +60°C |
| Storage
temperature |
-40
to +70°C |
| Humidity
range |
35
to 85% RH (non-condensing) |
| Insulation
resistance |
Min.
20M (with 500Vdc megger) |
| Dielectric
strength |
500Vac
for one minute |
| Vibration
resistance |
1.5mm
double amplitude, 10 to 55Hz in each
of X, Y and Z directions for 2 hours |
| Shock
resistance |
490m/s2
in each of X, Y and Z direction 10 times |
| Protection |
IP67
(IEC Standard) |
| Wiring
method |
Pre-leaded |
| Cord |
4.2mm
dia., 0.2mm 2 (11/0.16) section area,
2m long sheath color/No. of cores: Gray/3
leads (thru scan model: Black/2-cores) |
| Material |
Case:
Zinc die-cast, Lens: PMMA resin (protected
by glass) |
| Weight |
Approx.
105g (both emitter and receiver for
thru scan type), body only with cable |
| Others |
Reverse
power connection protection, False operation
protection at power supply (approx.
70ms), Output short protection |