| Detection method |
Thru scan |
Polarized retroreflective |
Diffuse scan |
| Model |
General |
High function |
General |
High function |
Transparent
object detection |
Short distance |
Long distance |
| Catalog listing |
HPA-T 1
HPA-T 2 |
HPA-T 3
HPA-T 4 |
HPA-P 1
HPA-P 2 |
HPA-P 3
HPA-P 4 |
HPA-F11
HPA-F21 |
HPA-D 1
HPA-D 2 |
HPA-A 1
HPA-A 2 |
| Supply voltage |
10
to 30Vdc (ripple not over 10%) |
| Current consumption |
50mA
max. (Note 1)
Emitter 20mA max.
Receiver 30mA max. |
40mA
max. (Note 1) |
| Scanning distance |
10m |
4m
(when used with FE-RR8 reflector) |
0.3 to 1m |
20cm |
80cm |
| Target object |
Opaque
object, 8mm dia. min. |
Opaque
object 80mm dia. min.
(when used with FE-RR8 reflector) |
- |
| Standard target object |
- |
- |
10 x 10cm
white
paper (Note 2) |
30 x 30cm
white
paper (Note 2) |
| Directional angle |
2
to 20° |
Sensor
body 1 to 5°, reflector 40° |
- |
| Differential travel |
- |
20% |
| Operation mode |
Light-operated/dark-operated
changeable by switch |
| Output mode |
NPN
or PNP transistor open collector |
| Control output |
Switching
current: 100mA max. (resistive load) Output dielectric strength:
30V max.
Residual voltage: 1V max. (at 100mA switching current), with
output short-circuit protection circuit |
| Self-diagnostic
output |
None |
Provided |
None |
Provided |
None |
None |
None |
Switching
current: 50mA max. (resistive load) Output dielectric strength:
30V max.
Residual voltage: 1V max. (at 50mA switching current), with
output short-circuit protection circuit |
| Response time |
0.5ms
max. for both
operation and reset |
1ms
max. for both
operation and reset |
0.5ms
max. for both
operation and reset |
5ms max.
for both
operation and reset |
| Sensitivity adjustment |
2-turn
potentiometer with an indicator |
| Light emitter |
Red
LED |
Infrared
LED |
| Indicator |
Other
than thru emitter; Light-operated (LO) indicator: Red (ON during
LO), Stability indication: Green [ON during stable LO or DO
(dark-operated), flashing during self-diagnostics] Thru emitter;
Power indicator: Red (ON while power is supplied), HPA-E13 with
SET mode indication: Green light ON |
| Operating ambient light |
Incandescent
lamp: Max. 5,000lx, Sun light: Max. 20,000lx |
| Operating ambient temperature |
-25
to +60°C (Note3) |
| Storage temperature |
-40
to +70°C |
| Humidity range |
35
to 85%RH (non-condensing) |
| Insulation resistance |
20M min. (by 500Vdc megger) |
| Dielectric strength |
1,000Vac,
50/60Hz for 1min. between casing and electrically active metals |
| Vibration |
10
to 55Hz, 1.5mm peak-to-peak amplitude, 2 hours each in X, Y,
and Z directions |
| Shock |
490m/s
2 repeated 10 times in X, Y, and Z directions |
| Protection |
IP67
(IEC standard) |
| Wiring method |
Pre-leaded,
pre-leaded quick connect, quick connect |
| Weight |
About
55g (body only), with 2m cable |
| Others |
Equipped
with a power ON/OFF malfunction prevention circuit (about 100ms)
and reverse connection protection circuit |