Self-contained Photoelectric Sensors with High Functions
Features

Strobe light emission permits easy confirmation of the    sensing range (high performance thru scan and polarized    retroreflective)

 The high margin regulation function permits adjustment of    the sensing range at a margin three times greater than    usual (high performance thru-scan and polarized    retroreflective).

 The front incoming light display facilitates adjustment of the    sensing range (thru scan)

• The Output Inhibit function permits secure adjustment of the    sensing range while debugging the PLC (high performance    thru scan and polarized retroreflective)

 An automatic pulse-phase shift system enhances mutual    interference prevention (polarized retroreflective type and    diffuse scan)

 The binary latching self-diagnostic function permits online    checking of incoming light for instability/ shielded status.

 A high sealing monoblock housing (IP67)

 Universal Features sealign (PNP, DIN, mounting)

 A polarized retroreflective type for transparent object    detection is available.

 Diffuse scan small-spot detection is realized by a narrow-   view lens attachment (spot dia: 2mm).
 
Specifications
Detection method Thru scan Polarized retroreflective Diffuse scan
Model General High function General High function Transparent object detection Short distance Long distance
Catalog listing HPA-T1
HPA-T2
HPA-T3
HPA-T4
HPA-P1
HPA-P2
HPA-P3
HPA-P4
HPA-F11
HPA-F21
HPA-D1
HPA-D2
HPA-A1
HPA-A2
Supply voltage 10 to 30Vdc (ripple not over 10%)
Current consumption 50mA max. (Note 1)
Emitter 20mA max.
Receiver 30mA max.
40mA max. (Note 1)
Scanning distance 10m 4m (when used with FE-RR8 reflector) 0.3 to 1m 20cm 80cm
Target object Opaque object, 8mm dia. min. Opaque object 80mm dia. min.
(when used with FE-RR8 reflector)
-
Standard target object - - 10 x 10cm white
paper (Note 2)
30 x 30cm white
paper (Note 2)
Directional angle 2 to 20° Sensor body 1 to 5°, reflector 40° -
Differential travel - 20%
Operation mode Light-operated/dark-operated changeable by switch
Output mode NPN or PNP transistor open collector
Control output Switching current: 100mA max. (resistive load) Output dielectric strength: 30V max.
Residual voltage: 1V max. (at 100mA switching current), with output short-circuit protection circuit
Self-diagnostic output None Provided None Provided None None None
Switching current: 50mA max. (resistive load) Output dielectric strength: 30V max.
Residual voltage: 1V max. (at 50mA switching current), with output short-circuit protection circuit
Response time 0.5ms max. for both
operation and reset
1ms max. for both
operation and reset
0.5ms max. for both
operation and reset
5ms max. for both
operation and reset
Sensitivity adjustment 2-turn potentiometer with an indicator
Light emitter Red LED Infrared LED
Indicator Other than thru emitter; Light-operated (LO) indicator: Red (ON during LO), Stability indication: Green [ON during stable LO or DO (dark-operated), flashing during self-diagnostics] Thru emitter; Power indicator: Red (ON while power is supplied), HPA-E13 with SET mode indication: Green light ON
Operating ambient light Incandescent lamp: Max. 5,000lx, Sun light: Max. 20,000lx
Operating ambient temperature -25 to +60°C (Note3)
Storage temperature -40 to +70°C
Humidity range 35 to 85%RH (non-condensing)
Insulation resistance 20M min. (by 500Vdc megger)
Dielectric strength 1,000Vac, 50/60Hz for 1min. between casing and electrically active metals
Vibration 10 to 55Hz, 1.5mm peak-to-peak amplitude, 2 hours each in X, Y, and Z directions
Shock 490m/s 2 repeated 10 times in X, Y, and Z directions
Protection IP67 (IEC standard)
Wiring method Pre-leaded, pre-leaded quick connect, quick connect
Weight About 55g (body only), with 2m cable
Others Equipped with a power ON/OFF malfunction prevention circuit (about 100ms) and reverse connection protection circuit
Installation Instructions No.: CP-UM-3098E
Note 1: About 30mA consumption current increases at triple alignment operation.
Note 2: KODAK 90% white paper is used.
Note 3: The triple alignment function should be used within the range of 5 to 30°C.
 
   

Address: 3323 Kifer Rd.; Santa Clara, CA; 95051 Phone: 1-866-SENSOR1 Fax: 1-602-216-8211
---------------------------------------------------------------------------------------------------------------------------------------------------------