FL7M Series
[Click the picture for pdf file]

Features:
2-wire type for both AC and DC. Wiring hours greatly reduced
Stable sensing area displayed by setting indicator (green/red LED)
Indicator lamp can be confirmed even from the rear side (pre-leaded type, pre-leaded connector type)
Compact and space saving (Overall length of M12 is 55mm, M18 48mm and M30 50mm.)
High seal capabilities (IP 67)
Enhanced circuit protection (surge absorption, load short- circuit)

 

Specification

Catalog listing FL7M-3T7HD-CN
FL7M-3T7HW(-CN, -CN03)
FL7M-7T7HD-CN
FL7M-7T7HW(-CN, -CN03)
FL7M-10T7W-CN
FL7M-10T7W(-CN, -CN03)
Actuation method High-frequency oscillation type (shielded)
Rated sensing distance 3±0.3mm 7±0.7mm 10 mm
Usable sensing distance 0 to 2.4mm 0 to 5.6mm 0 to 8mm
Standard target object 12 x 12mm, 1mm thick iron 18 x 18mm, 1mm thick iron 30 x 30mm, 1mm thick iron
Differential travel 10% max. of sensing distance
Rated supply voltage 100/200Vac, 50/60Hz 24Vdc
Operating voltage range 40 to 250Vac,20 to 250Vdc 20 to 250Vac/dc
Leakage current When AC power supply is used: 2.0mA max. (100/200Vac), When DC power supply is used: 1mA max. (24Vdc)
Control output Switching current: 5 to 100mA (at 30Vdc supply voltage: 5 to 20mA)
Voltage drop: When AC power supply is used 10V max., When DC power supply is used 6V max.
Output dielectric strength: 250V (at both AC and DC power supplies)
Operating frequency When AC power supply is used 25Hz
When DC power supply is used 1000Hz
When AC power supply is used 25Hz
When DC power supply is used 500Hz
When AC power supply is used 25Hz
When DC power supply is used 400Hz
Temperature characteristics ±10% max. for the range of -25 to +70°C when +23°C is taken as standard temperature in sensing distance
Operating temperature range -25 to +70°C
Storage temperature range -40 to +85°C
Insulation resistance 50M min. (at 500Vdc)
Dielectric strength 4,000Vac, 50/60Hz for 1 minute
Vibration resistance 10 to 55Hz, 1.5mm peak-to-peak amplitude, 2 hrs in X, Y and Z directions
Shock resistance 1000m/s2 10 times in X, Y and Z directions
Protection IP67 (IEC standard), IP67G (JEM standard)
Weight Approx. 110g
Main unit with 2m pre-leaded cable
Approx. 140g
Main unit with 2m pre-leaded cable
Approx. 240g
Main unit with 2m pre-leaded cable
Circuit protection Surge absorption, load short-circuit protection (at 20 to 30Vdc)
Wiring method Connector, pre-leaded connector, pre-leaded
Material Sensor Case Ni-plated brass (W type: Ni-plated brass, fluorine resin coated)
Sensing face PBT (W type: fluorine resin)
Connector Housing -CN: Ni-plated brass, -CN03: polyester elastomer
Holder Glass-lined polyester resin
Contact Gold-plated brass
 

Address: 3323 Kifer Rd.; Santa Clara, CA; 95051 Phone: 1-866-SENSOR1 Fax: 1-602-216-8211
---------------------------------------------------------------------------------------------------------------------------------------------------------
Yamatake Sensing Control, Limited. © Copyright 2007 Terms and Conditions | Privacy Policy