| Catalog listing |
LJS-E 312 |
LJS-E 512 |
|
Standards |
Conformed standards |
Product related:
IEC 60947-5-1, EN 60947-5-1
(->)
Machine related: IEC 60204-1, EN 60204-1, EN 1088 |
| Approved standards |
UL/CSA |
|
Structure |
Protective
structure |
IP67 (JIS
C 0920), (IEC 60529) |
| Electrical
shock protection |
class I (IEC
60536) |
| Internal switch |
Slow action |
| Lock method |
Locked when
the solenoid is not energized. |
Locked when
the solenoid is energized. |
Electrical
performance |
Body |
Electrical
rating |
AC-15: 24/48V
6A
DC-13: 24/48V 0.55A |
| Rated energizing
current (Ith) |
6A |
| Short-circuit
protective device |
Breaking fuse
10A type gG (gl) |
| Rated insulation
voltage (Ui) |
500V IEC 60947-1,
300V UL508/CSA |
Conditional
rated
short-circuit current |
1,000A |
Rated impulse
withstanding
voltage (Uimp) |
4,000V |
|
Solenoid coil |
Load factor |
100% |
| Rated insulation
voltage |
AC/DC 24V |
Allowable
voltage
variation range |
~20%, +10% |
| Electrical
life |
Average life:
20,000hrs. |
| Power consumption |
Rush: 10VA,
Retention: 10VA |
|
LED indicator |
Rated insulation
voltage |
50V |
| Rated current |
7mA (1 unit) |
| Rated voltage |
AC/DC 24/48V |
| Allowable
voltage variation |
AC/DC 20 to
52V |
| Electrical
life |
Average life:
100,000hrs. |
performance
performance |
Impact resistance |
100m/s2 (11ms)
IEC 60068-2-27 |
| Vibration resistance |
50m/s2 (10
to 500Hz) IEC 60068-2-6 |
| Tongued key
operating speed |
0.01m/s to
0.5m/s |
| Mechanical
operating frequency |
10 operations/min. |
|
Life |
Mechanical
life |
1million operations
or more |
| Electrical
life |
1million operations
or more |
Environmental
conditions |
Operating temperature
range |
~25 to +40°C
(non-freezing) |
| Operating humidity
range |
85%RH or less |
Recommended
tightening torque |
Body |
5 to 6Nm (M5
hexagon socket head cap bolt) |
| Cover |
1.5 to 3.0Nm
(M5 round head screw), 1.5Nm (M4 round head screw) |
| Terminal |
0.8Nm (M3
binding machine screw) |