3 Detection Modes 6 Tuning Modes
Relative Level Indication Other Features
Specifications
 
Basic Specs
 
 
Supply voltage 12 to 24 V DC ± 10 % (ripple 10 % p-p max.)
Power consumption 750 mW max. (current consumption 30 mA at power supply voltage 24 V DC)
Scanning distance (at max. sensitivity setting) Standard At use with HPF-T003: 800 mm
At use with HPF-D003: 300 mm
Ultra long distance At use with HPF-T003: 1,400 mm
At use with HPF-D002: 500 mm
High speed response At use with HPF-T003: 150 mm
At use with HPF-D002: 50 mm
Detection object Non-transparent object of more than 1 mm dia. (at use with HPF-T003)
Standard detection object White paper (at use with HPF-D002)
Hysteresis 20 % max. (at rated scanning distance)
Operation mode Light operated/dark operated changeover (Settig by L-ON/D-ON changeover switch)
Output mode N-MOS FET open drain output P-MOS FET open drain output
Control output Switching current: 100 mA max. (resistive load), Output dielectric strength: 26.4 V, Voltage drop: 2 V max. (at switching current 100 mA), With power short-circuit protection circuit
Response time Standard 1 ms max. for both operation and recovery
Ultra long distance 5 ms max. for both operation and recovery
High speed response 120 µs max. for operation and recovery
Delay Adjustable ON/OFF delay (1 ms to 1 s: 1 ms to 200 ms by 1 ms step, 200 ms to 1 s by 100 ms step)
One-shot output Adjustable ON/OFF (1 ms to 1 s: 1 ms to 200 ms by 1 ms step, 200 ms to 1 s by 100 ms step)
Light emitter Red LED
Digital indicator Incoming light level, setting status and contrast indication
Display functions Operation indicator, mode indication (RUN, SET, TMR and ADJ)
Ambient light immunity Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max.
Oeprating temperature range -20 to +55 °C (See note)
Storage temperature range -40 to +70 °C
Humidity range 35 to 85 % RH (no condensation allowed)
Insulation resistance 20 Mohms min. (at 500 V DC)
Dielectric strength 1,000 V AC 50/60 Hz for one min. between electrically live metals and case
Vibration resistance 10 to 55 Hz, 1.5 mm peak-to-peak amplitude, for 2 hrs. in each of X, Y and Z directions
Shock resistance 500 m/s2, 3 times in each of X, Y and Z directions
Weight Approx. 65 g (body only with 2 m cable)
Others Output is disabled during Power On (approx. 200 msec), Output reverse connection protection circuit
Note. Operating temperature range depends on the number of gang-mounted units.
[1 to 2 units: -20 to +55, 3 units: -20 to +50, 4 to 5units: -20 to +45, 6 units : -20 to +40]
Do not apply gang-mounting method if the operating temperature becomes higher than the above-listed temperatures.
 