HPQ Series

Features:
Detection method minimizes errors caused by bubbles & water droplets
Output mode selectable for presence/absence of liquid
Operation section mounted on side, so even when sensor is gang-mounted: LED is easily visible; and Output selector switch is accessible
Built-in circuits prevent malfunction (erroneous output) at power-up and protect against reversed polarity in power supply

 
Basic Specs
 
Detection method Slot type, transmission refraction
Supply voltage 10 to 28 V DC (ripple voltage 10 % max.)
Current consumption 25 mA max.
Applicable pipe diamer 8 to 13 mm dia.
Applicable pipe materials Fluorocarbon resin/glass
Applicable medium Transparent or non-transparent liquid
Detection hysteresis 1 mm max.
Operation mode Light Operated (L-ON)/dark operated (D-ON), switch selectable
At liquid detection: Dark, At liquid non-detection: Light
Output mode NPN transistor, Open collector type
Control output Switching current 100 mA max. (resistive load)
Output dielectric strength 30 V
Voltage drop 1 V max. (at 100 mA switching current)
Response time 2 ms max. (for operation and release)
Sensitivity adjustment Not available
Light emitter Red LED (peak emission wavelength 950 nm)
Display functions Operation indicator: red (lit at output ON)
Ambient light immunity 1,000 lux max. (incandescent lamp)
Operationg temperature range -10 to + 55 °C
Storage temperature range -25 to + 70 °C
Humidity range 35 to 85 % RH (condensation not allowed)
Insulation resistance Min. 20 Mohms (by 500 V DC megger)
Dielectric strength 1,000 V AC, 50/60 Hz for 1 min. between case and electrically live metals
500 V AC, 50/60 Hz for 1 min., at L-ON/D-ON selector switch
Vibration resistance 10 to 55 Hz, 1.5 mm peak-to-peak amplitude, 2 hrs. in X, Y and Z directions
Shock resistance 500 m/s2 (approx. 50 G) 3 times in X, Y and Z directions
Protective structure IP 50 (IEC 529)
Circuit protection Built-in reverse connection protection circuit, malfunction prevention circuit at power ON (approx. 20 ms), output short-circuit protection
Accessories Bunding band silicon tube (2 of each)

Address: 3323 Kifer Rd.; Santa Clara, CA; 95051 Phone: 1-866-SENSOR1 Fax: 1-602-216-8211
---------------------------------------------------------------------------------------------------------------------------------------------------------