| Scanning method |
Thru-scan |
Polarized retroreflective |
Direct reflecting type |
| Catalog listing |
 |
 |
 |
| Supply voltage |
10 to 30 V DC |
| Current consumption |
55 mA max. Emitter: 30
mA
Receiver: 25 mA |
30 mA max. |
30 mA max. |
| Scanning distance |
10 m |
2.5 m (when reflector FE-RR8
is used) |
0.5 m |
| Detection object |
Opaque object 9 mm dia.
min. |
Opaque object 80 mm dia.
min.
(when reflector FE-RR8 is used) |
- |
| Standard target object |
- |
- |
20 ~ 20 cm white paper |
| Scanning angle |
2 to 20 ° |
Body: 1 to 10 °, reflefctor:
40 ° min. |
- |
| Differential travel |
- |
- |
20 % max.(within rated
sensing distance) |
| Operation mode |
Set operation
mode selection line.
Operation mode selection line open or 0V connection: Light
ON/Vcc connection: Dark ON |
| Output mode |
 |
: NPN transistor output,
|
 |
: PNP transistor output, open collector |
|
| Control output |
Switching current: 100 mA max. (resistive load)
Output dielectric strength: 30 V
Voltage drop: 2 V max. (at 100 mA switching circuit) |
| Response time |
1 ms max. (for
operation and recovery) |
| Light emitter |
Infrared LED |
Red LED |
Infrared LED |
| Indicator lamps |
Other than thru-scan
emitter: output ON indicator (oange), stability indicator
(green)
Thru-scan emitter: power indicator (orange) |
Ambient light immunity
(at light receiving surface) |
Incandescent lamp 5,000 lx max., sunligh 20,000 lx
max. |
| Opearting temperature range |
-25 to + 60 °C
(icing, condensation not allowd) |
| Operating humidity range |
35 to 85 % RH
(icing, condensation not allowd) |
| Storage humidity range |
-40 to + 7 °C
(icing, condensation not allowd) |
| Insulation resistance |
20 Mohms min.
(by 500 V DC megger) |
| Dielectric strength |
1,000 V AC, 50/60
Hz for 1 min. between case and electrically live metals |
| Vibration resistance |
10 to 55 Hz,
1.5 mm peak-to-peak amplitude, 2 hrs. in X, Y and Z directions |
| Shock resistance |
500 m/s2
10 times in X, Y and Z directions |
| Protection |
IP 67 (IEC standard) |
| Wiring method |
Pre-leaded |
| Weight |
Approx. 60 g
(body only, with 2 m cord) |
| Circuit protection |
Reverse connection
protection circuit, output short-circuit protection circuit,
power ON malfunction prevention circuit (approx. 50 ms) |