| Detection method |
Thru scan |
Polarized retroreflective |
Diffuse scan |
| Model |
General |
High function |
General |
High function |
Transparent object detection |
Short distance |
Long distance |
| Catalog listing |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| Supply voltage |
10 to 30 V DC
(ripple not over 10 %) |
| Current consumption |
50 mA max. (Note
1)
Emitter 20 mA max.
Receiver 30 mA max. |
40 mA max. (Note
1) |
| Scanning distance |
10 m |
4 m (when used
with FE-RR8 reflector) |
0.3 to 1 m |
20 cm |
80 cm |
| Detection object |
Opaque, object,
ø 8 mm min. |
Opaque object,
ø 80 mm min.
(when used with FE-RR8 reflector) |
- |
| Standard detection object |
- |
- |
10 ~ 10 cm white paper
(Note 2) |
30 ~ 30 cm white paper
(Note 2) |
| Scanning angle |
2 to 20 ° |
Sensor body 1
to 5 °, reflector 40 ° |
- |
| Differential travel |
- |
20% |
| Operation mode |
Light-operated/dark-operated switch selectable |
| Output mode |
NPN or PNP transistor
open collector |
| Control output |
Switching current: 100 mA max. (resistive load) Output
dielectric strength: 30 V max.
Residual voltage: 1 V max. (at 100 mA switching current),
with output short-circuit protection circuit |
| Self-diagnostic output |
None |
Provided |
None |
Provided |
None |
None |
None |
Switching current: 50 mA max. (resistive load) Output
dielectric strength: 30 V max.
Residual voltage: 1 V max. (at 50 mA switching current),
with output short-circuit protection circuit |
| Response time |
0.5 ms max. for
both operation and reset |
1 ms max. for
both operation and reset |
0.5 ms max. for
both operation and reset |
5 ms max. for both operation
and reset |
| Sensitivity adjustment |
2-turns potentiometer
with an indicator LED |
| Light emitter |
Red LED |
| Display functions |
Other than thru
emitter: Light-operated (LO) indicator: Red (ON during
LO), Stability indicatoin: Green [ON during stable LO
or DO (dark-operated ), flashing during self-diagnostics]
Thru-emitter, Power indictor: Red (ON while power is supplied),
HPA-E13 |
| Ambient light immunity |
Incandescent lamp: Max. 5,000 lx, Sun light: Max.
20,000 lx |
| Operating ambient temperature |
-25 to +60 °C
(Note 3) |
| Storage temperature |
-40 to +70 °C |
| Humidity range |
35 to 85 % RH
(Non-condensing) |
| Insulation resistance |
20 Mohms min.
(by 500 V DC megger) |
| Dielectric strength |
1,000 V AC, 50/60
Hz for 1 min. between case and electrically live metals |
| Vibration resistance |
10 to 55 Hz,
1.5 mm peak-to-peak amplitude, 2 hrs. each in X, Y, and
Z directions |
| Shock resistance |
490 m/s2
{50 G}, repeated 10 times in X, Y, and Z directionsndard) |
| Protective structure |
IP 67 (IEC standard) |
| Wiring method |
Pre-leaded, pre-leaded quick connect, quick connect |
| Weight |
About 55 g (body
only), with 2 m cable |
| Others |
Equipped with a power ON / OFF malfunction prevention
circuit (about 100 ms) and reverse connection protection
circuit |