search »
» About us
» Integrated Solutions
» Sensor
» Switches
» Process Products
» VIP Access
» Document Download

Get Adobe Acrobat Reader

In order to view PDF documents, you need Adobe Acrobat Reader version 4.0 or later, available for free download from Adobe Systems (click icon to access the web site).
HPA Series Photoelectric Sensors

HPA Series HPA Series

Features:
Optical axis position easily confirmed with strobe light (through-scan & polarized retroreflective high-performance models)
High margin adjustment capability allows 3 times the conventional margin for optical axis alignment (high-performance through-scan & polarized retroreflective types)
Incoming-light display on front enables simple optical axis alignment (through-scan types)
Output Inhibit function facilitates optical axis adjustment during PLC debugging (high-performance through-scan & polarized retroreflective types)
Automatic pulse phase shift offers significant improvement in mutual interference prevention (polarized retroreflective and diffuse-scan types)
On-site confirmation of unstable detection possible with binary latching self-diagnostics
Monoblock molding with excellent sealing characteristics (IP67)
Suitable for overseas use (PNP & DIN rail)
Polarized retroreflective type available for transparent target detection
Small-spot (2 mm dia.) detection possible using a diffuse-scan type with narrow-view lens attachment

 
Basic Specs
 
Detection method Thru scan Polarized retroreflective Diffuse scan
Model General High function General High function Transparent object detection Short distance Long distance
Catalog listing
Supply voltage 10 to 30 V DC (ripple not over 10 %)
Current consumption 50 mA max. (Note 1)
Emitter 20 mA max.
Receiver 30 mA max.
40 mA max. (Note 1)
Scanning distance 10 m 4 m (when used with FE-RR8 reflector) 0.3 to 1 m 20 cm 80 cm
Detection object Opaque, object, ø 8 mm min. Opaque object, ø 80 mm min.
(when used with FE-RR8 reflector)
-
Standard detection object - - 10 ~ 10 cm white paper (Note 2) 30 ~ 30 cm white paper (Note 2)
Scanning angle 2 to 20 ° Sensor body 1 to 5 °, reflector 40 ° -
Differential travel - 20%
Operation mode Light-operated/dark-operated switch selectable
Output mode NPN or PNP transistor open collector
Control output Switching current: 100 mA max. (resistive load) Output dielectric strength: 30 V max.
Residual voltage: 1 V max. (at 100 mA switching current), with output short-circuit protection circuit
Self-diagnostic output None Provided None Provided None None None
Switching current: 50 mA max. (resistive load) Output dielectric strength: 30 V max.
Residual voltage: 1 V max. (at 50 mA switching current), with output short-circuit protection circuit
Response time 0.5 ms max. for both operation and reset 1 ms max. for both operation and reset 0.5 ms max. for both operation and reset 5 ms max. for both operation and reset
Sensitivity adjustment 2-turns potentiometer with an indicator LED
Light emitter Red LED
Display functions Other than thru emitter: Light-operated (LO) indicator: Red (ON during LO), Stability indicatoin: Green [ON during stable LO or DO (dark-operated ), flashing during self-diagnostics] Thru-emitter, Power indictor: Red (ON while power is supplied), HPA-E13
Ambient light immunity Incandescent lamp: Max. 5,000 lx, Sun light: Max. 20,000 lx
Operating ambient temperature -25 to +60 °C (Note 3)
Storage temperature -40 to +70 °C
Humidity range 35 to 85 % RH (Non-condensing)
Insulation resistance 20 Mohms min. (by 500 V DC megger)
Dielectric strength 1,000 V AC, 50/60 Hz for 1 min. between case and electrically live metals
Vibration resistance 10 to 55 Hz, 1.5 mm peak-to-peak amplitude, 2 hrs. each in X, Y, and Z directions
Shock resistance 490 m/s2 {50 G}, repeated 10 times in X, Y, and Z directionsndard)
Protective structure IP 67 (IEC standard)
Wiring method Pre-leaded, pre-leaded quick connect, quick connect
Weight About 55 g (body only), with 2 m cable
Others Equipped with a power ON / OFF malfunction prevention circuit (about 100 ms) and reverse connection protection circuit
(Note 1) About 30 mA consumption current increases at triple alignment operation.
(Note 2) CODAIC 90 % white paper is used.
(Note 3) The triple alignment function should be used whithin the range of +5 to +30 °C.

Address: 3323 Kifer Rd.; Santa Clara, CA; 95051 Phone: 1-866-SENSOR1 Fax: 1-602-216-8211
---------------------------------------------------------------------------------------------------------------------------------------------------------
Yamatake Sensing Control, Limited. © Copyright 2007 Terms and Conditions | Privacy Policy